Special requirements

    

5.2.6 cable into the line should be entered through the roof rack, unless accompanied by overhead cabinets located in the equipment room floor. Such as
With overhead cabinets located in the equipment room floor, due at the end of the cable into the cabinet line-bit.
5.2.7 Cabinets screwdriver bolt should be firmly on the ground.
5.2.8 All protective shield for the shell and the accessories for the manufacture of standard models.
5.2.9 of the cabinets should be low in the former covered with two back-up in accordance with GB1002-1996 of the 10A,
Standard 220V outlet. This socket should be connected to 220VAC power supply equipment, power supply socket and from contractors
Contractors.
5.2.10 equipment cabinets to be installed at depths exceeding 800mm internal fluorescent lighting, automatic door
Bright lighting for inside maintenance.
5.2.11 should pay particular attention to the cooling rack, such as exhaust fans should be located in the cabinet in order to ensure that the equipment cabinets in the
Environment acceptable, even when the failure of air-conditioning equipment cabinets can function properly. For
Contractor should be submitted to the temperature inside the equipment cabinet, the cabinet can be to prove that the maintenance of equipment within temperature specification
Temperature for the engineer for approval.
5.2.12 equipment layout should enable every pieces of equipment removed from the external touch and get to replace.
5.2.13 regardless of color and trim, cabinets, enclosures and other under the protection of public areas and materials should be exposed near the
Consistent with the built environment, which meet the requirements may be the difference between the various stations. These were exposed
The color and finishing materials of the samples should be submitted to the production of the project engineer for approval.
5.2.14 Except as otherwise provided, in the tunnel, station hall, the entrance of the site and the installation of the equipment, components, cables and distribution
Items should be non-reflective nature.
Electronic assemblies and components 5.3
5.3.1 Each insert components or printed circuit boards must be able to insert the main system strong, and with the support structure to a fixed
Components or circuit boards. In addition to computer equipment, the port can not use print.
5.3.2 the need for printed circuit board thickness sufficient to ensure its mechanical strength, to avoid the installation and maintenance of
Circuit board damage.
5.3.3 according to the standard printed circuit board design and production, including the conductor of the standard thickness, width and spacing
And so on. Equipment under different circumstances need different criteria selected.
5.3.4 Printed circuit board can not use the jumper circuit.
5.3.5 plug-in module to be obvious to all easy to identify, label module module need to include the name, part number, serial
And its revised version number.
5.3.6 plug-in module or printed circuit board LED display devices need to show the power and intelligence components of the work
Status. LED display devices to be visible.
5.3.7 for static sensitive electronic components needed to take appropriate protective measures.